Super Osseo integration High Speed Dental implants Reformation Chair side Excimer UV system

Super Osseo integration


Features  The surface modification system for improving the biocompatibility by photochemical reaction using an excimer UV wavelength 172nm.

Easy to use by only a start switch without pre-heating,

  • Space saving type, suitable for table top use
  • High speed processing time 2 min.
  • Equipped with the timer to set processing time
  • Equipped with ozon decomposition unit
  • Equipped with uniform irradiation processing mechanism to the test piece
  • Mercury lamp not in use. Mercury-free Environmentally friendly

 Specifications

Model UV172DT
Light source Excimer UV lamp
Wavelength 172nm
Wavelength 110mm
Power AC180-240V, 50/60Hz, 2A
Measurement W262 x D295 x H375 mm
Weight Approx. 11 kg
https://youtu.be/5CraEZIHlbg

Enhanced osseointegration is made possible by the improved success rate and stability of biocompatibility during implant treatment due to Excimer UV technology of the Super UV-OSSEO system This product is the medical applied technology of a UV surface reforming developed by semiconductor production from the 1970s

What is the implant surface modification by the excimer UV?
UV Surface modification for dental implant Excimer presents an advanced Excimer UV product capable of super osseo integration by the improved biocompatibility through enhanced success rate and stability of the surface of titanium for dental implant treatment. Through surface modifications on the implant material by the Excimer UV system, improvement in the affinity (wettability)between the implant body and the blood is realized. This is advantageous to acquire osseo integration. Excimer UV causes cutting of organic bonding on the surface of implant surface. Excimer UV is capable of improving performance of implant better by removing substances blocking wettability through the reaction of active oxygen and ozone gas from the surface of implant surface. Excimer UV is capable of improving performance of implant better by removing substances blocking wettability through the reaction of active oxygen and ozone gas from Excimer UV which produces gas of 10 times more ozone gas in comparison with a conventional mercury lamp. As a result, affinity improves with an implant body surface and blood. The associativity with the bone improves and thereby contributes to Super Osseo integration.
Excellence in comparison with conventional techniques In the shorter wavelength light, the performance improvement of surface-reforming becomes higher through processes, such as organic bonding to be cut, decomposition and reaction, in comparison with a conventional mercury UV. In addition, conventional mercury UV needs to be heated up for several minutes before the maximum output is reached. In case of Excimer UV system, however, the maximum output can be reached only in 2 minutes.
Exhibition The 44th Annual Meeting of the Japanese Society of Oral Implantology 2015
International Society of Oral Implantology 2015 DGZI Japan section

Application Tags:

biocompatibility
Excimer surface modification
Excimer uv @en
Implant
Ti ASTM F67
インプラント @en
エキシマ @en
生体親和性 @en

Other products that from [ Healthcare Instruments ]

Contact Us

  • 23-15, Mominokidai, Aoba-ku Yokohama-shi, Kanagawa, 225-0026, Japan
  • info@excimer.co.jp
  • TEL:+81-45-507-3313
  • Monday - Friday:
    9:00 am - 17:00 pm
    Saturday - Sunday: Closed

Are recommending the most suitable model fitting your use and environment through our long, abundant experience
Contact us here

Contact Us
  • Address:
    23-15, Mominokidai, Aoba-ku Yokohama-shi, Kanagawa, 225-0026, Japan
  • TEL:+81-45-507-3313
  • Email: info@excimer.co.jp
  • Monday - Friday: 9:00 am - 17:00 pm
    Saturday - Sunday: Closed
Movie
© 2007-2018. Excimer Inc. All right reserved.